Venturi Calculator: Flow, Throat Velocity and Throat Pressure

Work out the flow through a venturi from the pressure drop between the pipe and the throat, or the other way round, and find the pressure at the throat to see whether a side port would suck air in.

Calculated from standard textbook formulas, with every step shown. The formulas are fixed, so the working does not need checking: what matters is the numbers you type in. Use these calculators only if you are competent to choose the inputs (loads, material strength, dimensions, supports) and check your units and assumptions. For learning and checking your own working: design and sign-off are for a qualified engineer. Drafting Central does not store the numbers you type.

How this calculator works

A venturi squeezes the pipe down to a throat and then opens it out again. The same flow has to pass through a smaller area, so the liquid speeds up. To gain that speed it gives up pressure, so the pressure at the throat is lower than in the pipe. The faster the throat speed, the bigger the drop.

Choose whether you want the flow (from a measured pressure drop, as in a venturi meter) or the pressure drop (from a known flow). Enter the pipe and throat diameters, the density of the liquid, the discharge coefficient, and the inlet pressure. The calculator gives the velocities, checks them against Bernoulli, and works out the pressure at the throat.

If the throat pressure falls below atmospheric pressure, a side port connected to the air will draw air in. That is how a venturi aerator or ejector works. If it falls all the way to the vapour pressure of the liquid, the liquid boils at the throat (cavitation) and the formula stops being valid.

Formulas used

  • \beta = \dfrac{D_2}{D_1}
  • Q = C_d\,A_2\sqrt{\dfrac{2\,\Delta p}{\rho\,(1-\beta^4)}}
  • \Delta p = \dfrac{\rho}{2}\left(\dfrac{Q}{C_d A_2}\right)^2(1-\beta^4)
  • p_2 = p_1 - \Delta p

Worked example

With the default numbers in the calculator above:

  1. Diameter ratio: 0.50
  2. Pipe and throat areas: 1963.50 mm2 (pipe) and 490.87 mm2 (throat)
  3. Velocity-of-approach factor: 0.94
  4. Flow from the pressure drop: 7.03 L/s
  5. Velocity in the pipe and in the throat: 3.58 m/s in the pipe and 14.33 m/s in the throat
  6. Check with Bernoulli: the pressure given up to speed: 96.04 kPa from the speeds, and 96.04 kPa from the pressure drop (they match)
  7. Pressure at the throat (gauge): 100.00 kPa gauge
  8. Pressure at the throat (absolute): 201.33 kPa absolute

Change the numbers in the calculator to see the full working, every step, for your own case.

A second worked example

A different case, with these numbers: What do you want to find? The pressure drop and throat pressure, from the flow.

  1. Diameter ratio: 0.50
  2. Pipe and throat areas: 1963.50 mm2 (pipe) and 490.87 mm2 (throat)
  3. Velocity-of-approach factor: 0.94
  4. Pressure drop for this flow: 99.05 kPa
  5. Velocity in the pipe and in the throat: 3.57 m/s in the pipe and 14.26 m/s in the throat
  6. Check with Bernoulli: the pressure given up to speed: 95.13 kPa from the speeds, and 95.13 kPa from the pressure drop (they match)
  7. Pressure at the throat (gauge): 100.95 kPa gauge
  8. Pressure at the throat (absolute): 202.27 kPa absolute

Common questions

Why does the pressure fall at the throat?

The liquid has to speed up to push the same flow through the smaller area. Bernoulli's equation says the energy for that extra speed comes from the pressure, so the pressure at the throat is lower than in the pipe.

What discharge coefficient should I use?

A well-made venturi meter is usually about 0.97 to 0.99. The value depends on the shape and on the Reynolds number, so use the maker's figure for anything that matters. Use 1 for the ideal case.

When does a venturi draw air in?

When the absolute pressure at the throat is below atmospheric, so the gauge pressure there is negative. A port at the throat open to the air then pulls air in. How much air depends on the port size and the flow, which this calculator does not work out.

What is cavitation in a venturi?

If the pressure at the throat falls to the vapour pressure of the liquid, the liquid boils there and forms vapour bubbles. They collapse again downstream and can damage the pipe. It is avoided with a bigger throat, a lower flow or a higher inlet pressure.

Related calculators

Got a question about this? Ask an engineering question and get a plain-language answer with references.

Further reading: Standard fluid mechanics texts (continuity and Bernoulli). The venturi meter equation and discharge coefficients are covered in ISO 5167-4 (Venturi tubes).

Need a calculator we do not have?

Tell us what you would like to calculate. We read every request and build the most asked-for ones.

We store your request (and your email if you give it) to decide what to build. We do not store the numbers you type into calculators.

Embed this calculator on your own page

Copy this code into your page. The calculator runs inside the frame and links back to Drafting Central.

Need this drawn, designed or checked?

Drafting Central is a mechanical engineering and drafting business working with customers across Australia and around the world. A calculator gives you the numbers; we can turn them into drawings and designs.

Need help with a real project?

Talk to Drafting Central →

← All engineering calculators