Pile Group Reaction Calculator: Load on Each Pile from a Column Load and Moments
Find out how much load each pile of a pile group takes when a column sits on a pile cap, including the weight of the cap and the bending moments about both axes.
Engineering student calculators
Free textbook calculators with every step shown, so you can check your own working. Pick one, type in your numbers and see the formulas worked out. Or switch to Ask a question for an explained answer. No account needed.
Calculated from standard textbook formulas, with every step shown. The formulas are fixed, so the working does not need checking: what matters is the numbers you type in. Use these calculators only if you are competent to choose the inputs (loads, material strength, dimensions, supports) and check your units and assumptions. For learning and checking your own working: design and sign-off are for a qualified engineer. Drafting Central does not store the numbers you type.
How this calculator works
A pile cap is stiff, so when a column load and moments act on it the cap moves as a flat plane. Each pile (taken as identical) takes an equal share of the vertical load, plus or minus an extra amount that grows in a straight line across the group: the further a pile is from the centre of the group on the loaded side, the more it takes.
Enter the factored column load, the moments Mx and My about the centroid of the pile group, and the position of each pile, one per line. The calculator adds the weight of the cap, finds the centroid of the group and gives the reaction on every pile, the largest and the smallest. A negative answer means that pile is in uplift (tension).
It works for any number of piles and any layout, including groups that are not symmetrical. It also checks that the reactions add up to the load and give back the moments, and compares the largest reaction with the pile capacity you enter.
Formulas used
- N_t = N + k_f\,L_c B_c H_c\,\gamma
- R_i = \dfrac{N_t}{n} + \dfrac{M_x\,y_i}{\sum y^2} + \dfrac{M_y\,x_i}{\sum x^2}
- R_i = \dfrac{N_t}{n} + a\,x_i + b\,y_i,\quad a = \dfrac{M_y I_x - M_x I_{xy}}{I_x I_y - I_{xy}^2},\; b = \dfrac{M_x I_y - M_y I_{xy}}{I_x I_y - I_{xy}^2}
Worked example
With the default numbers in the calculator above:
- Number of piles and the centroid of the group: 4 piles, centroid at x = 0 m, y = 0 m
- Weight of the cap: 615.86 kN (volume 21.38 m3)
- Total vertical load on the group: 8115.86 kN
- Share of the axial load on each pile: 2028.96 kN
- Group second moments about the centroid: 5.76 m2 (sum of y squared), 5.76 m2 (sum of x squared), 0.00 m2 (sum of x times y)
- Load change per metre across the group: 69.44 kN per metre in x and 260.42 kN per metre in y
- Reaction on pile 1 (x = -1.2, y = -1.2): 1633.13 kN
- Reaction on pile 2 (x = 1.2, y = -1.2): 1799.80 kN
- Reaction on pile 3 (x = -1.2, y = 1.2): 2258.13 kN
- Reaction on pile 4 (x = 1.2, y = 1.2): 2424.80 kN
- Largest pile reaction: 2424.80 kN on pile 4
- Smallest pile reaction: 1633.13 kN on pile 1
Change the numbers in the calculator to see the full working, every step, for your own case.
A second worked example
A different case, with these numbers: Column axial load (factored, downward) 1000 kN; Moment Mx about the centroid of the pile group (adds load to the piles at positive y) 200 kN m; Moment My about the centroid of the pile group (adds load to the piles at positive x) -100 kN m; Pile positions, one per line: x then y in metres, measured from any origin the list of values shown in the calculator; Cap length 0 m; Design compression capacity of one pile (0 to skip the check) 0 kN.
- Number of piles and the centroid of the group: 3 piles, centroid at x = 1 m, y = 0.5 m
- Weight of the cap: 0.00 kN (volume 0.00 m3)
- Total vertical load on the group: 1000.00 kN
- Share of the axial load on each pile: 333.33 kN
- Group second moments about the centroid: 1.50 m2 (sum of y squared), 2.00 m2 (sum of x squared), 0.00 m2 (sum of x times y)
- Load change per metre across the group: -50.00 kN per metre in x and 133.33 kN per metre in y
- Reaction on pile 1 (x = 0, y = 0): 316.67 kN
- Reaction on pile 2 (x = 2, y = 0): 216.67 kN
- Reaction on pile 3 (x = 1, y = 1.5): 466.67 kN
- Largest pile reaction: 466.67 kN on pile 3
- Smallest pile reaction: 216.67 kN on pile 2
- Check: the reactions add up to the load and give the moments: 1000.00 kN, and moments 200.00 and -100.00 kN m (Mx = 200.00, My = -100.00)
Common questions
What does the rigid cap assumption mean?
The cap does not bend, so it settles and tilts as one flat plane. Each pile then carries a share of the load that varies in a straight line across the group. A flexible cap or piles of different stiffness change the shares.
Where do I measure the moments from?
From the centroid of the pile group. If the column is not over the centre, add the column load times its offset to the moment first. The calculator finds the centroid of the piles for you, so you can measure positions from any origin.
What if a pile reaction is negative?
That pile is in uplift, so it needs a tension check: skin friction for pulling out, and the connection to the cap. Many designers change the layout so every pile stays in compression.
Is this a pile cap design?
No. It gives the pile loads only. The pile itself is designed to AS 2159, the cap (bending, shear, strut and tie) to AS 3600, with the right load combinations, by an engineer.
Related calculators
Got a question about this? Ask an engineering question and get a plain-language answer with references.
Further reading: Standard foundation engineering texts (rigid pile cap method, linear distribution of pile loads). Pile design is in AS 2159 and the cap in AS 3600.
Need a calculator we do not have?
Embed this calculator on your own page
Copy this code into your page. The calculator runs inside the frame and links back to Drafting Central.
Need this drawn, designed or checked?
Drafting Central is a mechanical engineering and drafting business working with customers across Australia and around the world. A calculator gives you the numbers; we can turn them into drawings and designs.
Need help with a real project?
Talk to Drafting Central →