Outrigger Mat Pressure Calculator: Ground Pressure under a Crane or Jack Mat

The pressure a crane outrigger or jack mat puts on the ground, compared with the allowable ground pressure, and the smallest mat that keeps it under that limit.

Calculated from standard textbook formulas, with every step shown. The formulas are fixed, so the working does not need checking: what matters is the numbers you type in. Use these calculators only if you are competent to choose the inputs (loads, material strength, dimensions, supports) and check your units and assumptions. For learning and checking your own working: design and sign-off are for a qualified engineer. Drafting Central does not store the numbers you type.

How this calculator works

Enter the outrigger reaction from the load chart or lift plan, the mat width and length, and the allowable ground pressure from the engineer or geotechnical report.

Add the weight of the mat if it is heavy. The calculator divides the total by the mat area to get the pressure.

It says pass or fail against the allowable pressure and gives the smallest mat area and the smallest square mat.

Formulas used

  • q = \frac{P + W_{mat}}{B\,L}
  • A_{min} = \frac{P + W_{mat}}{q_a}
  • s = \sqrt{A_{min}}

Worked example

With the default numbers in the calculator above:

  1. Mat area: 1.44 m²
  2. Load on the ground (reaction plus mat weight): 400.00 kN
  3. Ground pressure under the mat: 277.78 kPa
  4. Allowable ground pressure: 150.00 kPa
  5. Pressure used against the allowable: 185.19 percent
  6. Pressure check: FAIL: pressure is over the allowable
  7. Smallest mat area for the allowable pressure: 2.67 m²
  8. Smallest square mat (side): 1.63 m

Change the numbers in the calculator to see the full working, every step, for your own case.

A second worked example

A different case, with these numbers: Mat width 1.7 m; Mat length 1.7 m.

  1. Mat area: 2.89 m²
  2. Load on the ground (reaction plus mat weight): 400.00 kN
  3. Ground pressure under the mat: 138.41 kPa
  4. Allowable ground pressure: 150.00 kPa
  5. Pressure used against the allowable: 92.27 percent
  6. Pressure check: PASS: pressure is under the allowable
  7. Smallest mat area for the allowable pressure: 2.67 m²
  8. Smallest square mat (side): 1.63 m

Common questions

Where do I get the allowable ground pressure?

From a geotechnical report or the engineer for the site. Do not guess it, because ground varies and wet, filled or disturbed ground can be much weaker.

Is a pass the same as a safe lift?

No. This is a simplified check that assumes the pressure is the same over the whole mat. It leaves out mat stiffness, an off-centre load, soft layers, slopes, water, buried services and shock loads. A lift needs a lift plan and a competent person.

Why is the outrigger reaction bigger than the load?

It includes the weight of the crane and the way the load sits, and it is highest on the outrigger nearest the load. Take it from the crane maker load chart.

Related calculators

Got a question about this? Ask an engineering question and get a plain-language answer with references.

Further reading: AS 2550.1 Cranes, hoists and winches: safe use, general requirements; the crane maker load chart; the geotechnical report for the site.

Need a calculator we do not have?

Tell us what you would like to calculate. We read every request and build the most asked-for ones.

We store your request (and your email if you give it) to decide what to build. We do not store the numbers you type into calculators.

Embed this calculator on your own page

Copy this code into your page. The calculator runs inside the frame and links back to Drafting Central.

Need this drawn, designed or checked?

Drafting Central is a mechanical engineering and drafting business working with customers across Australia and around the world. A calculator gives you the numbers; we can turn them into drawings and designs.

Need help with a real project?

Talk to Drafting Central →

← All engineering calculators