Motor Sizing Calculator from Load Torque and Speed
The motor power needed for a load at a speed, and the next standard motor size.
Engineering student calculators
Free textbook calculators with every step shown, so you can check your own working. Pick one, type in your numbers and see the formulas worked out. Or switch to Ask a question for an explained answer. No account needed.
Calculated from standard textbook formulas, with every step shown. The formulas are fixed, so the working does not need checking: what matters is the numbers you type in. Use these calculators only if you are competent to choose the inputs (loads, material strength, dimensions, supports) and check your units and assumptions. For learning and checking your own working: design and sign-off are for a qualified engineer. Drafting Central does not store the numbers you type.
How this calculator works
The power at the driven shaft is the torque times the angular speed. The motor must supply that power plus the losses in the gearbox and couplings, so divide by the efficiency, and multiply by a service factor to allow for overload and starting duty.
The calculator then gives the next standard IEC motor rating. If you give the inertia of the load and the time to reach speed, it also gives the torque and power needed to accelerate it. The motor must also deliver the starting torque and not overheat in repeated starts: check the motor data with the supplier.
Formulas used
- P = T\,\omega,\quad \omega = \frac{2\pi N}{60}
- P_{motor} = \frac{P \cdot SF}{\eta}
- T_a = \frac{J\,\omega}{t_a}
Worked example
With the default numbers in the calculator above:
- Power at the driven shaft: 2.513 kW
- Motor power needed for the running load: 3.415 kW
- Next standard motor size: 4 kW
Change the numbers in the calculator to see the full working, every step, for your own case.
Common questions
What service factor should I use?
About 1.15 to 1.5 depending on the duty. Conveyors, crushers and shock loads are towards the high end.
What are standard motor sizes?
The common IEC ratings: 0.37, 0.55, 0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 11, 15, 18.5, 22, 30, 37, 45, 55, 75, 90 kW and up.
Does it check starting torque?
No. A loaded conveyor or crusher may need several times its running torque to start, so check the motor torque-speed curve.
Related calculators
Further reading: Motor and gearbox manufacturers' selection guides; Shigley, Mechanical Engineering Design.
Need a calculator we do not have?
Embed this calculator on your own page
Copy this code into your page. The calculator runs inside the frame and links back to Drafting Central.
Need this drawn, designed or checked?
Drafting Central is a mechanical engineering and drafting business in Burleigh Waters on the Gold Coast. A calculator gives you the numbers; we can turn them into drawings and designs.
Need help with a real project?
Talk to Drafting Central →